Technical Specifications for INDUCTION FURNACES ( INGOT / BILLET UNITS )

Description

01. Furnace Capacity (Kgs)

3500

4000

5000

6000

7000

8000

10000

12000

15000

18000

20000

22000

25000

02. MF Power (KW)

1750

2000

2250

2500

3000

3500

4000

5000

6000

7000

7500

8000

8500

03. Transformer Capacity (KVA)

2190

2500

2825

3125

3750

4500

5000

6250

7500

8750

9500

10000

10500

04. Solid State Power Panel Efficiency

97%

05. Frequency (Hz)

500

06. Maximum Mains (KVA)

1940

2215

2440

2710

3255

3880

4340

5425

6510

7600

8310

8865

9420

07. Mains PF (min at rated mains voltage & max power setting)

Better than 0.95

08. Load Matching

By automatic frequency shifting with constant power tracking

09. Steel Melting Rate @ 1675 deg cent for steel scrap 100% yield (Kgs/Hr)

3200

3600

4050

4500

5400

6300

7000

8800

10500

12200

13200

14000

15000

10. Energy Consumption @ 1675 deg cent for steel scrap 100% yield (KWH/Ton)

540

540

530

11. DM Water Requirement (Litre)

1000

1000

1250

1250

1500

1500

1500

1500

2000

2000

2500

2500

2500

12. Over Head Storage Tank Capacity (Litre)

30000

32000

35000

35000

35000

50000

50000

50000

50000

60000

60000

80000

80000

13. Cooling Tower Duty in LPM for temp drop from 42 deg cent to 32 deg cent

1575

1800

2000

2250

2700

3200

3600

4500

5400

5300

6750

7200

7650

14. Underground Storage Tank Capacity (Litre)

90000

100000

100000

100000

100000

150000

150000

150000

150000

200000

200000

250000

250000